Seven precautions for server radiator installation?
浏览次数:3680 日期:2019-01-21
(1) Precautions for server radiator installation
When installing the server radiator, aluminum-plastic pipes must be connected with joints and cannot be bent, otherwise it will easily lead to pipeline leakage. Each interface must be tangled, and the interface and the aluminum-plastic pipe should be kept in the same horizontal position to avoid water pressure and pressure on the joint, resulting in water leakage at the interface.
(2) Precautions for installing the server radiator
After installing the server radiator, you should use a pressing machine to suppress the pressure of about 10 kg to check whether there is water leakage.
(3) Precautions for installing the server radiator
Improper installation of the server radiator can easily cause damage. Neither leather sofas nor wooden furniture are suitable for long-term heating, and people are not suitable for being too close to the radiator for a long time. Therefore, do not install the radiator near the rest area.
(4) Precautions for server radiator installation
When installing a heavy radiator, a ground bracket must be installed for support.
(5) Precautions for server radiator installation
Wrap the radiator when installing the server radiator to increase energy consumption. It is wrong to wrap the radiator for the sake of beauty, because the heat cannot be released after the radiator is covered, which not only affects the room temperature, but also makes the water temperature inside the radiator increase and blocks the energy consumption of heating, which reduces both Efficacy also improves energy consumption. In addition, the outer cover also brings safety risks to radiator maintenance and repair.
(6) Precautions for server radiator installation
Mixed installation of radiators of multiple materials can cause malfunction. The living room and bedroom are made of good materials, and the kitchen and bathroom space are made of general materials. This approach seems to be light and heavy. It saves a little money, but it will cause hidden heating risks. Experts clearly stated that the installation of radiators of different materials in the same system may damage the inner surface of the light radiator or damage the protective layer; and the electronic potential is different, it may also cause water leakage; in addition, due to equipment changes, there is also a malfunction Hidden dangers.
(7) Precautions for server radiator installation
After the server radiator is installed, it is safe to use. It is necessary to keep people in the house during heating water test. During the use of the radiator and after stopping the heating, check whether the various connectors of the radiator are loose or leaking, if found If the radiator is leaking, it is necessary to notify the installation unit for maintenance in a timely manner, and it is strictly forbidden for non-professionals to disassemble or modify the radiator without permission.